Zendure SuperBase Pro 2000

On one charge the Zendure SuperBase Pro 2000 runs a typical refrigerator about 17 hours, and runs an older furnace blower about 9 hours.

2,096 Wh battery (1,701 usable)2,000 W output4,000 W peak

We found no Amazon listing for this exact model (checked November 1, 2026). What we rejected and why.

Buy this instead: PECRON F3000LFP, $899. It holds at least as much (3,072 Wh) and puts out at least as much (3,600 W), and Amazon sells it today.

PECRON F3000LFP: $899 at Amazon

Planning figures: a typical refrigerator averages about 83 W; an older furnace blower averages about 182 W. Yours may use less or more; the range is in the table below. How long other power stations run a refrigerator. A furnace blower is wired in: it needs an inlet or transfer switch fitted by an electrician.

Wall recharge
up to 1,800 W from the wall
Recalls
no CPSC recall names this exact model (screened 2026-10-09)

How long it runs each appliance

Hours on one charge: Zendure SuperBase Pro 2000Bar chart. Fridge: about 17 hours; Furnace blower, older single-speed: about 9 hours; Furnace blower, variable-speed: about 12 hours; CPAP: about 24 hours; Sump pump: about 12 hours; Wi-Fi router and modem: about 38 hours; Laptop: about 24 hours.Fridge17 hFurnace blower, older single-speed9 hFurnace blower, variable-speed12 hCPAP24 hSump pump (may not start a hard-starting one)12 hWi-Fi router and modem38 h+14 hLaptop24 h+0.4 h
Hours on one full charge, one appliance at a time, at a typical draw. Each battery is one day; each block is 2 hours. Past a day the battery is full and the figure beside it says how many hours past.
The same numbers as a table
ApplianceTypical average drawHours on one charge
Fridge83 Wabout 17 h
Furnace blower, older single-speed182 Wabout 9 h
Furnace blower, variable-speed132 Wabout 12 h
CPAP55 Wabout 24 h
Sump pump136 Wabout 12 h (may not start a hard-starting one)
Wi-Fi router and modem24 Wabout 38 h
Laptop52 Wabout 24 h

The range behind that

This is a 2,096Wh battery with 2,000W of output, which means it gives back about 1,701 watt-hours at a typical household load (estimated) and can run anything drawing up to 2,000 watts at once.

It runs indoors and makes no fumes. Of the 16 household loads we track, it can run 14 for at least part of a day. It would keep a refrigerator going for 12–24 hours, from a hard-working fridge to an efficient one.

These figures come from a non-US page

The source we captured for this model is a regional page, not the US one. The same product name can carry a different voltage and different outlets between regions, so treat these numbers as needing US confirmation.

https://us.zendure.com/de/pages/superbase-pro-2000-us-user-manual-english

Figures from the maker’s own pages and manual, with a link beside each one.

What it can run

LoadRunning / startingStarts it?TypicalRange
Wi-Fi router and modem 15–40 W starts it about 38h 29–48h
Phone charging and small USB devices 10–40 W starts it about 61h 39–73h
A few LED lights 15–80 W starts it about 48h 22–68h
Laptop and monitor 45–150 W starts it about 24h 11–45h
CPAP 30–100 W starts it about 24h 15–34h
Refrigerator/freezer 100–700 W
starts at up to 2,900 W
starts it about 17h 12–24h
Chest freezer 80–500 W
starts at up to 2,200 W
starts it about 24h 7.4–52h
Sump pump 700–1,500 W
starts at up to 4,500 W
may not start a hard-starting one about 12h 3.3–32h
Window air conditioner 500–3,250 W
starts at up to 7,200 W
may not start a hard-starting one about 2.5h 0.7–8.2h
Microwave 800–1,800 W starts it about 60 minutes of running time short bursts
Coffee maker 700–1,500 W starts it about 72 minutes of running time short bursts
Television 40–250 W starts it about 24h 6.7–52h
Garage door opener 300–800 W
starts at up to 1,800 W
starts it about 2 hours of running time short bursts
12 V compressor fridge (camping) 25–110 W
starts at up to 320 W
starts it about 44h 23–62h

Hours of use on one charge. Typical is the middle of our range for that appliance; the range runs from a hard-working unit to an efficient one. Short-burst loads (microwave, coffee maker, garage door) show running time at full power instead. “Starts it” means the peak output covers even a hard-starting one.

Specifications

Battery
2,096 Wh (about 1,701 Wh usable, estimated)
Continuous output
2,000 W
Peak output
4,000 W
Output voltage
120 V
Wall recharge
up to 1,800 W from the wall source
Solar input
up to 2,400 W source
Weight
46.7 lb (21.2 kg) source

Recall screen

No published recall names this exact model

No CPSC recall in the 2026-10-09 recall list names this exact model. No recall in the recall list we checked names this brand at all, so finding nothing here says less.

This check cannot clear your own unit. Most recalls cover only certain serial numbers. Read the model and serial number off the label on the unit itself, then check the maker's recall page before you use it, sell it, or buy it.

Use the CPSC recall search.

How we know the screen was not simply blind

Finding nothing only means something if the search could have found something. So we searched the same records for this brand and got 0 recalls. No recall in the recall list we checked names this brand at all, so finding nothing here says less than it would for a brand that does appear.