Champion 201444 5500W Inverter

The short answer

This generator makes up to 4,000 watts and can start motors that briefly need 5,500 watts. It runs on gasoline.

It supplies 120 volts only, so it cannot run 240-volt equipment such as a typical well pump. Of the 15 household loads we track, it can handle 15.

It must run outside. The exhaust contains carbon monoxide, which you cannot smell and which kills.

Outdoor use only

This generator burns fuel and produces carbon monoxide. Run it outdoors only, well away from doors, windows and vents, with the exhaust pointed away from the building. Fit working CO alarms indoors. CO Shield; manufacturer says this is not a substitute for an indoor CO alarm

What it can run

LoadDrawStartingVerdict
Wi-Fi router and modem 15–40W 40W Will work
Phone charging and small USB devices 10–40W 40W Will work
A few LED lights 15–80W 80W Will work
Laptop and monitor 45–150W 150W Will work
CPAP 30–100W 100W Will work
Refrigerator/freezer 100–700W 2,900W Will work
Chest freezer 80–500W 2,200W Will work
Gas-furnace blower 400–1,200W 3,500W Will work
Sump pump 700–1,500W 4,500W Will work
Window air conditioner 500–3,250W 7,200W Might work
Microwave 800–1,800W 1,800W Will work
Coffee maker 700–1,500W 1,500W Will work
Television 40–250W 250W Will work
Garage door opener 300–800W 1,800W Will work
12 V compressor fridge (camping) 25–110W 320W Will work

Runtime for a generator is a fuel question, not a capacity one — see the table above.

Output

Running wattswatts
Best case4,000 Plan for this4,000

Sustained output. This is what the generator can hold indefinitely.

Continuous output
4,000W
Starting / surge
5,500W
Output voltage
120V
120V only. It cannot run a 240V load such as a typical well pump at any wattage.
Starting method
Recoil
Weight
92.4 lb

Fuel and runtime

FuelRunningStartingTank Runtime at 50% load
Gasoline 4,000W 5,500W 2.2 gal not stated

Runtime is quoted at half load. Your actual runtime falls as load rises, and refuelling a hot generator is itself a burn and fire hazard — let it cool first.

Outlets

  • 120V 20A duplex 5-20R
  • 120V 30A TT-30R
  • parallel outlet
  • regulated 12V 8A automotive

Outlet configuration decides what you can plug in directly. Powering house circuits instead of appliances requires a transfer switch or inlet installed by a licensed electrician.

Safety boundary

  • Outdoor only. Carbon monoxide from this unit is lethal and undetectable by smell.
  • Backfeeding is prohibited. Never run a cord from this generator into a wall outlet. It can kill line workers restoring your power.
  • Any connection to building wiring requires a licensed electrician and, in most places, a permit and inspection.
  • Store fuel safely and away from the running unit. Let the engine cool before refuelling.

All safety boundaries →