Generac GP6500 COsense, 76723

We will not recommend this unit

Manufacturer variant/serial identity must be resolved against recall information before recommendation or commerce.

This unit appears in our research pages but is never ranked in a planner result and carries no buy link. If you already own one, read the model and serial number from the unit label and check the manufacturer's recall lookup and the CPSC recall database before using it.

The short answer

This generator makes up to 6,500 watts and can start motors that briefly need 8,125 watts. It runs on gasoline. At half load it runs about 11.5 hours on a tank.

It supplies both 120 and 240 volts, so it can run a well pump or other 240-volt equipment through proper transfer equipment. Of the 15 household loads we track, it can handle 0.

It must run outside. The exhaust contains carbon monoxide, which you cannot smell and which kills.

Outdoor use only

This generator burns fuel and produces carbon monoxide. Run it outdoors only, well away from doors, windows and vents, with the exhaust pointed away from the building. Fit working CO alarms indoors. COsense technology; follow manufacturer outdoor-use instructions

Output

Running wattswatts
Best case6,500 Plan for this6,500

Sustained output. This is what the generator can hold indefinitely.

Continuous output
6,500W
Starting / surge
8,125W
Output voltage
120/240V
Supplies 240V, so it can run a well pump or other 240V load — through correctly installed transfer equipment, never a cord into an outlet.
Starting method
Recoil
Weight
172 lb

Fuel and runtime

FuelRunningStartingTank Runtime at 50% load
Gasoline 6,500W 8,125W 7.9 gal 11.5h

Runtime is quoted at half load. Your actual runtime falls as load rises, and refuelling a hot generator is itself a burn and fire hazard — let it cool first.

Outlets

  • covered outlets; exact receptacle mix pending manual extraction

Outlet configuration decides what you can plug in directly. Powering house circuits instead of appliances requires a transfer switch or inlet installed by a licensed electrician.

Safety boundary

  • Outdoor only. Carbon monoxide from this unit is lethal and undetectable by smell.
  • Backfeeding is prohibited. Never run a cord from this generator into a wall outlet. It can kill line workers restoring your power.
  • Any connection to building wiring requires a licensed electrician and, in most places, a permit and inspection.
  • Store fuel safely and away from the running unit. Let the engine cool before refuelling.

All safety boundaries →